J. bras. pneumol ; 40(3): 294-303, May-Jun/2014. tab, graf
Article in English | LILACS | ID: lil-714686

ABSTRACT

Objective: Discomfort and noncompliance with noninvasive ventilation (NIV) interfaces are obstacles to NIV success. Total face masks (TFMs) are considered to be a very comfortable NIV interface. However, due to their large internal volume and consequent increased CO2 rebreathing, their orifices allow proximal leaks to enhance CO2 elimination. The ventilators used in the ICU might not adequately compensate for such leakage. In this study, we attempted to determine whether ICU ventilators in NIV mode are suitable for use with a leaky TFM. Methods: This was a bench study carried out in a university research laboratory. Eight ICU ventilators equipped with NIV mode and one NIV ventilator were connected to a TFM with major leaks. All were tested at two positive end-expiratory pressure (PEEP) levels and three pressure support levels. The variables analyzed were ventilation trigger, cycling off, total leak, and pressurization. Results: Of the eight ICU ventilators tested, four did not work (autotriggering or inappropriate turning off due to misdetection of disconnection); three worked with some problems (low PEEP or high cycling delay); and one worked properly. Conclusions: The majority of the ICU ventilators tested were not suitable for NIV with a leaky TFM. .


Objetivo: O desconforto e a falta de adaptação às interfaces de ventilação não invasiva (VNI) são obstáculos ao sucesso da VNI. A máscara facial total (MFT) é uma interface de VNI considerada muito confortável. No entanto, devido a seu grande volume interno e, consequentemente, ao aumento da reinalação de CO2, a MFT tem orifícios que permitem vazamentos proximais para melhorar a eliminação de CO2. É possível que os ventiladores usados na UTI não compensem esse vazamento adequadamente. Neste estudo, buscamos determinar se ventiladores de UTI com módulo de VNI podem ser usados com MFT com grandes vazamentos. Métodos: Estudo em simulador mecânico conduzido em um laboratório universitário de pesquisa. Oito ventiladores de UTI equipados para realizar VNI e um ventilador específico para VNI foram conectados a uma MFT com grandes vazamentos. Todos foram testados com dois níveis de positive end-expiratory pressure (PEEP, pressão expiratória final positiva) e três níveis de pressão de suporte. As variáveis analisadas foram disparo do ventilador, ciclagem, vazamento total e pressurização. Resultados: Dos oito ventiladores de UTI, quatro não funcionaram (autodisparo ou desligamento inapropriado por detecção incorreta de desconexão), três funcionaram com alguns problemas (valores baixos de PEEP ou grande atraso na ciclagem do ventilador) e apenas um funcionou adequadamente. Conclusões: A maioria dos ventiladores de UTI testados mostrou-se inadequada para VNI com MFT com grandes vazamentos. .


Subject(s)
Humans , Equipment Failure Analysis/standards , Masks/standards , Noninvasive Ventilation/instrumentation , Ventilators, Mechanical/standards , Computer Simulation , Equipment Design , Equipment Failure Analysis/methods , Intensive Care Units , Models, Biological , Masks/adverse effects , Noninvasive Ventilation/adverse effects , Ventilators, Mechanical/adverse effects
2.
J. bras. pneumol ; 39(5): 595-603, Sep-Oct/2013. tab, graf
Article in English | LILACS | ID: lil-695172

ABSTRACT

OBJECTIVE: To evaluate the performance of manual resuscitators (MRs) used in Brazil in accordance with international standards. METHODS: Using a respiratory system simulator, four volunteer physiotherapists employed eight MRs (five produced in Brazil and three produced abroad), which were tested for inspiratory and expiratory resistance of the patient valve; functioning of the pressure-limiting valve; and tidal volume (VT) generated when the one-handed and two-handed techniques were used. The tests were performed and analyzed in accordance with the American Society for Testing and Materials (ASTM) F920-93 criteria. RESULTS: Expiratory resistance was greater than 6 cmH2O . L−1 . s−1 in only one MR. The pressure-limiting valve, a feature of five of the MRs, opened at low pressures (< 17 cmH2O), and the maximal pressure was 32.0-55.9 cmH2O. Mean VT varied greatly among the MRs tested. The mean VT values generated with the one-handed technique were lower than the 600 mL recommended by the ASTM. In the situations studied, mean VT was generally lower from the Brazilian-made MRs that had a pressure-limiting valve. CONCLUSIONS: The resistances imposed by the patient valve met the ASTM criteria in all but one of the MRs tested. The pressure-limiting valves of the Brazilian-made MRs usually opened at low pressures, providing lower VT values in the situations studied, especially when the one-handed technique was used, suggesting that both hands should be used and that the pressure-limiting valve should be closed whenever possible. .


OBJETIVO: Avaliar o desempenho de reanimadores manuais (RMs) utilizados no Brasil conforme critérios definidos por uma norma internacional. MÉTODOS: Utilizando um simulador do sistema respiratório, oito RMs manuais (cinco produzidos no Brasil e três importados) foram avaliados em relação a resistência inspiratória e expiratória da válvula para o paciente; funcionamento da válvula limitadora de pressão; e volume corrente (VT) gerado por quatro fisioterapeutas voluntários, utilizando uma ou duas mãos. Para a realização e análise dos testes, foram utilizados critérios sugeridos pela norma da American Society for Testing and Materials (ASTM) F920-93. RESULTADOS: A resistência expiratória foi superior a 6 cmH2O . L−1 . s−1 em apenas um dos RMs testados. A válvula limitadora de pressão, presente em cinco RMs, abriu em baixas pressões (< 17 cmH2O), e a pressão máxima variou de 32,0-55,9 cmH2O. Houve grande variação da média de VT obtido pelos diferentes RMs. Os valores médios de VT utilizando uma mão foram inferiores ao sugerido pela ASTM (600 mL). O VT médio, nas situações estudadas, foi geralmente menor nos RMs nacionais com válvula limitadora de pressão. CONCLUSÕES: As resistências impostas pela válvula do paciente estão de acordo com os critérios da ASTM, com exceção de um RM. As válvulas limitadoras de pressão dos RMs nacionais geralmente abrem em baixas pressões, determinando o fornecimento de um menor VT nas situações estudadas, principalmente com o uso de uma mão, o que sugere que a ventilação deva ser feita com as duas mãos e a válvula limitadora de pressão deva ser fechada sempre que possível. .


Subject(s)
Female , Humans , Male , Intensive Care Units , Resuscitation/instrumentation , Ventilators, Mechanical/statistics & numerical data , Brazil , Comparative Effectiveness Research/methods , Computer Simulation/standards , Observer Variation , Respiratory Mechanics/physiology , Tidal Volume , Ventilators, Mechanical/standards
3.
J. bras. pneumol ; 39(2): 205-213, mar.-abr. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-673312

ABSTRACT

OBJETIVO: Avaliar, em um modelo pulmonar simulando um paciente sob ventilação mecânica, a eficiência e a segurança da manobra de hiperinsuflação manual (HM) com o intuito de remover secreção pulmonar. MÉTODOS: Oito fisioterapeutas utilizaram um ressuscitador manual autoinflável para realizar HM com o objetivo de remover secreções, em duas condições: conforme rotineiramente aplicada durante sua prática clínica, e após receberem instruções verbais baseadas em recomendações de especialistas. Três cenários clínicos foram simulados: função pulmonar normal, doença pulmonar restritiva e doença pulmonar obstrutiva. RESULTADOS: Antes da instrução, o uso de duas compressões sequenciais do ressuscitador era comum, e a pressão proximal (Pprox) foi mais alta em relação à obtida após a instrução. Entretanto, a pressão alveolar (Palv) nunca excedeu 42,5 cmH2O (mediana, 16,1; intervalo interquartil [IQ], 11,7-24,5), mesmo com valores de Pprox de até 96,6 cmH2O (mediana, 36,7; IQ, 22,9-49,4). O volume corrente (VC) gerado foi relativamente pequeno (mediana, 640 mL; IQ, 505-735) e o pico de fluxo inspiratório (PFI) geralmente excedeu o pico de fluxo expiratório (PFE): 1,37 L/s (IQ, 0,99-1,90) e 1,01 L/s (IQ, 0,55-1,28), respectivamente. Uma relação PFI/PFE < 0,9 (que teoricamente favorece a migração do muco em direção às vias aéreas centrais) foi obtida em somente 16,7% das manobras. CONCLUSÕES: Nas condições testadas, a HM gerou valores seguros de Palv mesmo com altas Pprox. Entretanto, a HM foi comumente realizada de um modo que não favorecia a remoção de secreção (PFI excedendo PFE) mesmo após a instrução. A relação PFI/PFE desfavorável foi explicada pelas insuflações rápidas e o baixo VC.


OBJECTIVE: To evaluate, in a lung model simulating a mechanically ventilated patient, the efficiency and safety of the manual hyperinflation (MH) maneuver as a means of removing pulmonary secretions. METHODS: Eight respiratory therapists (RTs) were asked to use a self-inflating manual resuscitator on a lung model to perform MH as if to remove secretions, under two conditions: as routinely applied during their clinical practice; and after receiving verbal instructions based on expert recommendations. In both conditions, three clinical scenarios were simulated: normal lung function, restrictive lung disease, and obstructive lung disease. RESULTS: Before instruction, it was common for an RT to compress the resuscitator bag two times, in rapid succession. Proximal pressure (Pprox) was higher before instruction than after. However, alveolar pressure (Palv) never exceeded 42.5 cmH2O (median, 16.1; interquartile range [IQR], 11.7-24.5), despite Pprox values as high as 96.6 cmH2O (median, 36.7; IQR, 22.9-49.4). The tidal volume (VT) generated was relatively low (median, 640 mL; IQR, 505-735), and peak inspiratory flow (PIF) often exceeded peak expiratory flow (PEF), the median values being 1.37 L/s (IQR, 0.99-1.90) and 1.01 L/s (IQR, 0.55-1.28), respectively. A PIF/PEF ratio < 0.9 (which theoretically favors mucus migration toward the central airways) was achieved in only 16.7% of the maneuvers. CONCLUSIONS: Under the conditions tested, MH produced safe Palv levels despite high Pprox. However, the MH maneuver was often performed in a way that did not favor secretion removal (PIF exceeding PEF), even after instruction. The unfavorable PIF/ PEF ratio was attributable to overly rapid inflations and low V T.


Subject(s)
Humans , Lung , Pulmonary Disease, Chronic Obstructive/therapy , Pulmonary Ventilation/physiology , Respiratory Therapy/methods , Analysis of Variance , Models, Biological , Pulmonary Disease, Chronic Obstructive/physiopathology , Respiratory Therapy/education
4.
Clinics ; 67(10): 1157-1163, Oct. 2012. tab
Article in English | LILACS | ID: lil-653479

ABSTRACT

OBJECTIVES: The aim of this manuscript is to describe the first year of our experience using extracorporeal membrane oxygenation support. METHODS: Ten patients with severe refractory hypoxemia, two with associated severe cardiovascular failure, were supported using venous-venous extracorporeal membrane oxygenation (eight patients) or veno-arterial extracorporeal membrane oxygenation (two patients). RESULTS: The median age of the patients was 31 yr (range 14-71 yr). Their median simplified acute physiological score three (SAPS3) was 94 (range 84-118), and they had a median expected mortality of 95% (range 87-99%). Community-acquired pneumonia was the most common diagnosis (50%), followed by P. jiroveci pneumonia in two patients with AIDS (20%). Six patients were transferred from other ICUs during extracorporeal membrane oxygenation support, three of whom were transferred between ICUs within the hospital (30%), two by ambulance (20%) and one by helicopter (10%). Only one patient (10%) was anticoagulated with heparin throughout extracorporeal membrane oxygenation support. Eighty percent of patients required continuous venous-venous hemofiltration. Three patients (30%) developed persistent hypoxemia, which was corrected using higher positive end-expiratory pressure, higher inspired oxygen fractions, recruitment maneuvers, and nitric oxide. The median time on extracorporeal membrane oxygenation support was five (range 3-32) days. The median length of the hospital stay was 31 (range 3-97) days. Four patients (40%) survived to 60 days, and they were free from renal replacement therapy and oxygen support. CONCLUSIONS: The use of extracorporeal membrane oxygenation support in severely ill patients is possible in the presence of a structured team. Efforts must be made to recognize the necessity of extracorporeal respiratory support at an early stage and to prompt activation of the extracorporeal membrane oxygenation team.


Subject(s)
Adolescent , Adult , Aged , Female , Humans , Male , Middle Aged , Young Adult , Hypoxia/therapy , Extracorporeal Membrane Oxygenation/mortality , Respiratory Insufficiency/therapy , Brazil/epidemiology , Extracorporeal Membrane Oxygenation/methods , Length of Stay , Respiration , Time Factors , Treatment Outcome , Tertiary Care Centers/statistics & numerical data
5.
Pulmäo RJ ; 20(3): 43-48, 2011. ilus
Article in Portuguese | LILACS | ID: lil-619180

ABSTRACT

A lesão pulmonar induzida por ventilador mecânico (LPIV) é um efeito adverso da ventilação mecânica (VM). O conhecimentoda sua fisiopatologia tem permitido desenhar estratégias ventilatórias protetoras — baixo volume corrente associado àpositive end-expiratory pressure (PEEP, pressão expiratória final positiva) — para prevenir a LPIV em pacientes com síndrome do desconforto respiratório agudo, o que reduziu a mortalidade dessa síndrome. Apresentamos uma sucinta revisão sobre LPIV discutindo novos achados tanto em pulmões doentes quanto em pulmões saudáveis. A melhor compreensão da micromecânica pulmonar tem permitido identificar variáveis que melhor refletem os determinantes da lesão pulmonar: o excesso de tensão e de deformação do parênquima pulmonar. Mesmo em pulmões normais, o uso de volumes correntes habituais (8-10 ml/kg) associado a PEEP baixa pode determinar inflamação pulmonar e lesão pulmonar aguda. Portanto, novos métodos de ajuste individualizado da PEEP têm sido analisados. Meta-análises recentes têm apontado o benefício do uso de PEEP alta para minimizar a LPIV em pacientes com SDRA. O uso de marcadores de tensão e deformação pulmonares pode facilitar o ajuste individualizado de uma VM protetora. A LPIV também pode acontecer em pulmões previamente normais e em pacientes submetidos a suporte ventilatório por curto período, como durante o período intraoperatório.


Subject(s)
Humans , Male , Female , Pulmonary Atelectasis , Respiration, Artificial , Respiratory Distress Syndrome , Lung Diseases , Respiratory Therapy
6.
Rev. bras. ter. intensiva ; 19(3): 399-407, jul.-set. 2007. tab
Article in Portuguese | LILACS | ID: lil-470956

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: Em 2000, foi publicado o II Consenso Brasileiro de Ventilação Mecânica. Desde então, o conhecimento na área da ventilação mecânica avançou rapidamente, com a publicação de inúmeros estudos clínicos que acrescentaram importantes informações para o manuseio de pacientes críticos em ventilação artificial. Além disso, a expansão do conceito de Medicina Baseada em Evidências determinou a hierarquização das recomendações clínicas, segundo o rigor metodológico dos estudos que as embasaram. Essa abordagem explícita vem ampliando a compreensão e a aplicação das recomendações clínicas. Por esses motivos, a AMIB - Associação de Medicina Intensiva Brasileira - e a SBPT - Sociedade Brasileira de Pneumologia e Tisiologia - julgaram conveniente a atualização das recomendações descritas no Consenso anterior. Dentre os tópicos selecionados a Fisioterapia durante a Ventilação Mecânica foi um dos temas propostos. O objetivo foi descrever os pontos mais importantes relacionados à atuação do fisioterapeuta no ambiente da terapia Intensiva com ênfase na ventilação mecânica. MÉTODO: Objetivou-se chegar a um documento suficientemente sintético, que refletisse a melhor evidência disponível na literatura. A revisão bibliográfica baseou-se na busca de estudos através de palavras-chave e em sua gradação conforme níveis de evidência. As palavras-chave utilizadas para a busca foram: mechanical ventilation e physical therapy. RESULTADOS: São apresentadas recomendações quanto aos principais procedimentos fisioterápicos, as técnicas e suas aplicações. CONCLUSÕES: A fisioterapia ocupa hoje papel relevante no ambiente da terapia intensiva, principalmente para os pacientes sob ventilação mecânica invasiva ou não invasiva.


BACKGROUND AND OBJECTIVES: The II Brazilian Consensus Conference on Mechanical Ventilation was published in 2000. Knowledge on the field of mechanical ventilation evolved rapidly since then, with the publication of numerous clinical studies with potential impact on the ventilatory management of critically ill patients. Moreover, the evolving concept of evidence - based medicine determined the grading of clinical recommendations according to the methodological value of the studies on which they are based. This explicit approach has broadened the understanding and adoption of clinical recommendations. For these reasons, AMIB - Associação de Medicina Intensiva Brasileira and SBPT - Sociedade Brasileira de Pneumologia e Tisiologia - decided to update the recommendations of the II Brazilian Consensus. Physical therapy during mechanical ventilation has been one of the updated topics. This objective was described the most important topics on the physical therapy during mechanical ventilation. METHODS: Systematic review of the published literature and gradation of the studies in levels of evidence, using the key words: mechanical ventilation and physical therapy. RESULTS: Recommendations on the most important techniques applied during mechanical ventilation. CONCLUSIONS: Physical therapy has a central role at the Intensive Care environment, mainly in patients submitted to a mechanical ventilatory support invasive or non invasive.


Subject(s)
Breathing Exercises , Physical Therapy Modalities , Respiration, Artificial
8.
Rev. ABP-APAL ; 12(1/4): 25-30, jan.-dez. 1990. tab
Article in Portuguese | LILACS | ID: lil-198506

ABSTRACT

Os autores discutem as diferenças existentes entre mulheres alcoolistas (n=68) e homens alcoolistas (n=68), todos pacientes de um hospital público universitário. Foram pesquisados fatores demográficos e outras características ligadas ao uso do álcool. Verificou-se que os grupos em questäo diferem significativamente quanto à idade de aumento de ingestäo e quanto ao número de tentativas de suicídio, sendo semelhantes quanto às características estudadas. Os autores supöem que uma amostra maior possa confirmar estatísticamente outros dados e apontam a importância dessa linha de pesquisa, dado o aumento da populaçäo alcoolista feminina


Subject(s)
Humans , Male , Female , Alcoholism